Working Principle Of Step Down Transformer Pdf

Posted on by

Operation-of-voltage-stabilizer.jpg' alt='Working Principle Of Step Down Transformer Pdf' title='Working Principle Of Step Down Transformer Pdf' />RATIONAL SCC LINE TRAINING MANUAL Pdf Download. Training Manual Diagnostic and Troubleshooting SCC Line Self. Cooking Center Combi Master Edition 1. Training Manual Diagnostic and Troubleshooting SCC Line Edition 1. General hints Isolate the appliance from mains supply before opening the appliance When working with chemicals, i. After maintenance repair the appliance must be checked for electric safety. Working Principle Of Step Down Transformer Pdf FilePart 2 Topic SCC Technique Page SCC Overlay SCC Self Cooking Control until software 0. Books Never Written Math Beginning Your Exercise Program By. SCC Combi Steamer mode until software 0. SCC Self Cooking Control since software 0. English 5 1. INTRODUCTION AND SAFETY 1. Introduction and safety 1. Introduction Congratulations on your choice of an exceptionally high quality product. View and Download SICK CLV640 operating instructions manual online. CLV640 Barcode Reader pdf manual download. SCC Combi Steamer mode since software 0. SCC Programming, Clean. Jet SCC Principle SCC Operator PCB. CM Technique from 0. Steam Hot Air Combi Steam Low Temperature Steam Finishing Cool Down Cabinet temperature display Cabinet temperature setting Timer Core temperature Time Core temperature display Time Core temperature setting. Working Principle Of Step Down Transformer Pdf To Word' title='Working Principle Of Step Down Transformer Pdf To Word' />CM Technique from 0. Thermocouple cabinet Thermocouple quenching Steam control Thermocouple core temperature Thermocouple steam generator preheating, 1. C 3. 56F max Safety temperature limiter steam generator 1. C Safety temperature limiter cabinet 3. Working Principle Of Step Down Transformer Pdf EnC Solenoid valve lling Solenoid valve quenching Fan motor without jumper SC pump Level electrode. Water level control Steam Generator Center S2 Ground 2 6. V AC water level too low steam heating must switch OFF solenoid valve lling Y1 ON Center S2 Ground 0. V AC water level reached steam heating can switch ON solenoid valve. Steam Control CM from 0. Intelligent steam control via quenching sensor 1. Filling of interior cabinet based on time and temperature control of B1 cabinet sen 2. After steam saturation inside cabinet steam will also ll quenching chamber 3. Key code CM from 0. Cleaning program Cool down cabinet below 6. C Spray inside cabinet with Rational cleaner Close cabinet door Select Cool Down Press core temperature key for 1. CLEn will show in cabinet temperature display Press timer key 1x. Key code CM from 0. Changing temperature display from C to F Select any mode Press timer and core temperature key simultaneously for 1. Display changes from C to F or vice versa Release both keys 1. C 2. 12F Notes. CM PCB 4. CM PCB 4. 2. 0. 0. B3 Core temperature 0,1 AT 2 AT B1 Interior cabinet Transformer B2 Quenching Steam control B5 Steam generator ON OFF switch Buzzer 4. Level electrode 2 AT X 1. Motor for CM 4. 0. Jumper Jumper 4. 0. Jumper is not used on models 6. Service 3. 4 will be shown LED code fan motor SCC and CM from 0. Remedy Reason Check for motor blockage or change mo. Mode Steam 1. 00C 2. F Temp. preset, not adjustable Signal Remark Function Step Responsible sensor Select Steam mode Select time or core temperature Door open 1. VDC X2. 7 1 2 Close cabinet door Reed switch S3 Door closed 0. Depeche Mode Singles 81 Torrent more. VDC X2. 7 1 2 Solenoid Y1 energizes when X1. Mode Low temperature steam Temp. C 8. 6 2. 10F Signal Remark Function Step Responsible sensor Note Select vario steam mode Below 1. C 2. 12F fan at lowest speed when no energy required for longer than 2 minutes. Temp. setting 3. 0 9. C 8. 6 2. 10F Select time or core temperature Door open 1. VDC X2. 7 1 2 Close cabinet door. Mode Combination Temp. C 8. 6 5. 72F Signal Remark Function Step Responsible sensor Note Select Combination mode Below 1. C 2. 12F fan at lowest speed when no energy required for longer than 2 minutes. Temp. 3. 0 3. 00C 8. F Select time or core temperature Door open 1. VDC X2. 7 1 2 Close cabinet door. Mode Finishing Temp. C 8. 6 5. 72F Signal Remark Function Step Responsible sensor Note Select Finishing Below 1. C 2. 12F fan at lowest speed when no energy required for longer than 2 minutes. Recom. Temp. 1. 00 1. C 2. 12 2. 84F Select time or core temperature Door open 1. VDC X2. 7 1 2 Close cabinet door. Mode Hot Air Temp. C 8. 6 5. 72F Responsible sensor Signal Remark Function Step Note Select Hot Air Below 1. C 2. 12F fan at lowest speed when no energy required for longer than 2 minutes. Temp. 3. 0 3. 00C 8. F Select time or core temperature Door open 1. VDC X2. 7 1 2 Close cabinet door. Service level CM from 0. AT 2 AT Switch unit ON Transformer On operator PCB set DIP switch 1 to ON position 4. AT Select service package with timer dial 2 AT 2 AT F6. F6. 1 Diagnostic Program Error code history. Service level d. P Diagnostic Program d. P Description Connector Cabinet display Timer display Comment d. P 1 Software Version Software Software version C 1 Version 0. P 2 B1 Cabinet sensor actual value max value Reset by pressing for 5 sec. P 3 B2 Quenching sensor actual value. Service Level rt Running Time Timer display 1 9. Comment rt Description Temp. Reset by pressing rt 1 Total S3 door openings for 5 sec. Reset by pressing rt 2 Total time Y1 valve lling for 5 sec. Service level SE Basic settings Select desired step with timer dial fan motor and heating elements are automatically OFF Activate selected step with timer key SE 1 Steam heating time since last SC Automatic Press time and core key simultaneously for 5 seconds to set steam heating time to preset steam heating time plus 1 minute. Service Level SE Basic settings Adjusting speed of blower motor steam 1. After blower speed adjustment the original rpm is shown in the temp. SE 9,1. 0,1. 1 changed rpm is shown in the time display Press time key, keep it pressed and adjust displayed rpm with timer dial SE9 MIN rpm. Service level F Function test NOTE In Function test components are NOT protected against overload Function Connection Cabinet Time Comment IO PCB Display Display Steam 5. Electric unit X2. Gas B5 steam gene no function rator Steam 1. Electric unit X2. Service level F Function test NOTE In Function test components are NOT protected against overload Connection Cabinet Time Function Comment IO PCB Dispaly Display Actual blower Set CO Steam blower motor Check CO value MIN rpm value only Actual blower Steam blower motor Start rpm Adjust CO. Service Level ER Error code history Since software version C1 0. When Timer key is pressed the error code will be displayed, i. B1 Cabinet sensor defective Y1 Filling solenoid defective Er. Since software version C1 0. GE1. 1 No rpm signal. Failure Codes CM from 0. Int. cab. Timer Failure explanation Description display display OPEn H2. O open Lack of water open water tap CHn. G Change Polarity Phase Neutral only gas units Timer Int. Part concerned Description display display E press core temp. CM Gas from 0. 4 2. Ignition module Steam and Hot Air without jumper Thermocouple interior cabinet Thermocouple quenching Steam control Thermocouple core temperature Thermocouple steam generator Ignitionmonitoring electrode steam Ignitionmonitoring electrode hot air Safety thermostat steam generator 1. C Safety thermostat interior cabinet 3. C Fan motor SC pump. Basic info about CM Gas from 0. Identi cation of the different gas burners Gas blowers CM 2. CM 6. 1 6. 2 1. Steam Blower ignition box tted Hot Air blower top ignition box not tted Hot Air blower bottom ignition box. Sequence of events of Steam Hot Air Burner SCC as well as CM Max RPM Flame current Start RPM Min RPM Start up Pre purge Ignition Burner running Time 1. Ignition box gets heat demand over the BUS cable. Check Gas Type Gas Conversion CM Gas from 0. Microsoft Windows 7 Official .Iso Links (Digital River) on this page.